Before beginning work, ground yourself by touching something metal to discharge any static electricity. Static electricity can damage the board.
Do not subject the board to physical shocks.
For connection to the IEEE 1284 interface board, use a half pitch 36-pin interface cable.
Check the contents of the package.
IEEE 1284 Interface Board
Turn the printer off and unplug the power cord.
Loosen the two screws and remove the slot cover.
The removed cover will not be reused.
Fully insert the IEEE 1284 interface board.
Confirm that the IEEE 1284 interface board is firmly connected to the controller board.
Tighten the two screws to secure the interface board.
Plug in the power cord, and then turn on the printer.
Print the configuration page to confirm that the board was attached correctly.
Confirm that the board was correctly installed by printing the configuration page. If it is correctly installed, "Parallel Interface" will appear for "Device Connection" on the configuration page.
If the board was not installed properly, repeat the procedure from step 2. If it cannot be installed correctly even after reattempting installation, contact your sales or service representative.
For information on printing the configuration page, see "Test Printing", Quick Installation Guide.