User GuidePro C5300S/C5310S

Resetting the Replaceable Parts Counter

1Pull out the drawer until it stops.

machine illustration

2Turn the machine on.

3Access the Adjustment Settings for Skilled Operators menu.

Displaying the [Adjustment Settings for Skilled Operators] Button

4Press [Machine: Maintenance].

Operation panel screen illustration

5Press [Reset Replaceable Parts Counter].

Operation panel screen illustration

6Press the button of the part that has been replaced.

Operation panel screen illustration

7Press [plus] to enter the value "1", and then press [Clear].

Operation panel screen illustration

8Press [OK].

9Turn the machine off.

Turning Off/On the Power

10Push the drawer back into the machine.

machine illustration

11Turn the machine on.

The counter for the replaced component is reset. The setting for adjusting the machine for the replaced component is executed automatically.

12Access the Adjustment Settings for Skilled Operators menu.

Displaying the [Adjustment Settings for Skilled Operators] Button

13Press [Machine: Maintenance].

14Press [Replaceable Parts Counter].

15Make sure the counter has been reset.