Replacing the Developer

1Access the Adjustment Settings for Operators menu.

See "Accessing Adjustment Settings for Operators", Adjustment Item Menu Guide: TCRU/ORU.

2Open the front covers.

machine illustration

3Remove the 3 screws.

machine illustration

4Remove the cover.

machine illustration

5Attach the developer bottle.

machine illustration

6Press [Main Unit: Maintenance].

Operation panel screen illustration

7Press [Execute Developer Exhaust].

Operation panel screen illustration

8Press [Execute].

Discharge starts. It takes about 3 minutes.

9Check that developer discharge has completed, and then press [Check].

10Release the developer bottle's catch, and then remove the bottle.

machine illustration

11Remove the seal on the side of the bottle, and then affix it to the bottle's opening.

machine illustration

12Turn the new developer bottle a few times to loosen the developer.

machine illustration

13Attach the new developer bottle.

machine illustration

14Pull out the seal.

machine illustration

15Press [Execute Developer Fill].

Operation panel screen illustration

16Press [Execute Developer Fill].

17Press [Execute].

Replenishment starts. It takes about a minute.

18While pouring in the developer, tap the bottle a few times so that no developer is left in the bottle.

machine illustration

19Check that developer replenishment has completed, and then press [Check].

20Release the developer bottle's catch, and then remove the bottle.

machine illustration

Keep the bottle.

21Attach the cover by aligning it with the 3 catches.

machine illustration

22Secure the cover with the 3 screws.

machine illustration

23Reset the counter for replaceable parts.

See Resetting the Replaceable Parts Counter.