Skip header
 

Replacing the Cleaning Unit for Intermediate Transfer Belt

1Open the front covers.

machine illustration

2Pull down the 2 levers.

machine illustration

3Remove the 4 screws, and then remove the cover.

machine illustration

4Pull out the drawer until it stops.

machine illustration

5Remove the transfer unit.

See Replacing the Transfer Unit.

6Spread a sheet of paper.

machine illustration

7Push the drawer back into the machine.

machine illustration

8Remove the cleaning unit for photoconductor unit.

See Replacing the Charge Unit/Cleaning Unit for Photoconductor Unit/Photoconductor Unit.

9Pull up the 2 levers, and then remove the screw.

machine illustration

10Holding the grip, pull out the cleaning unit for intermediate transfer belt while pressing it to the left.

machine illustration

11Pull out the cleaning unit for intermediate transfer belt until it stops.

machine illustration

12While holding the latch, remove the cleaning unit for intermediate transfer belt.

machine illustration

13Engage the new cleaning unit for intermediate transfer belt with the guide rail.

machine illustration

14Push in the cleaning unit for intermediate transfer belt while pressing it to the left.

machine illustration

15Secure the cleaning unit for intermediate transfer belt with the screw.

machine illustration

16Pull out the drawer until it stops.

machine illustration

17Remove the paper.

machine illustration

18Push the drawer back into the machine.

machine illustration

19Turn the machine on.

See Turning Off/On the Power.

20Access the Adjustment Settings for Skilled Operators menu.

See "Adjustment Settings for Skilled Operators", Adjustment Item Menu Guide: TCRU/ORU.

21Press [Machine: Maintenance].

Operation panel screen illustration

22Press [ITB Manual Lubrication].

Operation panel screen illustration

23Press [Execute ITB Manual Lubrication].

Operation panel screen illustration

24Press [OK].

Operation panel screen illustration

25Close the front covers.

machine illustration

Lubrication starts. It takes about 5 minutes.

If lubrication fails soon after starting, check the following:

  • Is the cleaning unit for intermediate transfer belt attached?

  • Is the cleaning unit for photoconductor unit detached?

  • Has the toner run out or almost run out?

If this operation fails halfway, contact your sales or service representative.

26Check that lubrication has completed, and then press [Exit].

27Open the front covers.

machine illustration

28Attach the transfer unit.

See Replacing the Transfer Unit.

29Attach the cleaning unit for photoconductor unit.

See Replacing the Charge Unit/Cleaning Unit for Photoconductor Unit/Photoconductor Unit.

30Pull down the 2 levers.

machine illustration

31Attach the cover, and then secure it with the 4 screws.

machine illustration

32Pull up the 2 levers.

machine illustration

33Close the front covers.

machine illustration

34Reset the counter for replaceable parts.

Do not turn the machine on until you have read how to do so.