Skip header
 

Replacing the Charge Unit/Cleaning Unit for Photoconductor Unit/Photoconductor Unit

1Open the front covers.

machine illustration

2Remove the 3 screws.

machine illustration

3Remove the cover.

machine illustration

4Push the lock lever.

machine illustration

5Pulling the lock lever down, pull out the charge unit.

machine illustration

6Hold the charge unit with both hands so it does not come into contact with any metal parts, and then detach it.

machine illustration

7Pull down the lever.

machine illustration

8Remove the 3 screws, and then remove the cover.

machine illustration

9Loosen the drawer stop knob by turning it, and then remove it.

machine illustration

10Holding the handle, pull out the development unit drawer.

machine illustration

11Turn the lock lever.

machine illustration

12Remove the cleaning unit for photoconductor unit.

machine illustration

13Turn the drum knob.

machine illustration

14Rotate the handle.

machine illustration

15Pull out the photoconductor unit.

machine illustration

16Using the powder pad applicator, pat the surface of the photoconductor unit lightly.

machine illustration

17Spread the developer on the photoconductor unit evenly using a dry cloth.

machine illustration

18Rotate the photoconductor unit a half-turn until the surface to which the powder has been applied faces down.

machine illustration

19Attach the new photoconductor unit.

machine illustration

machine illustration

Make sure that the surface to which the powder has been applied does not come into contact with the development roller.

machine illustration

20Rotate the handle.

machine illustration

21Turn the drum knob while pushing it in to fasten the photoconductor unit.

machine illustration

22Check that the drum knob is locked securely.

Turn the drum knob until the groove (2) reaches the position to the right of reference position (1).

Unlocked

machine illustration

Locked

machine illustration

23Attach the new cleaning unit for photoconductor unit.

machine illustration

machine illustration

24Turn the lock lever, and then secure cleaning unit for photoconductor unit.

machine illustration

25While carefully holding the cleaning unit for photoconductor unit, rotate the photoconductor unit half a turn.

machine illustration

26Holding the handle, push the development unit drawer back into the machine.

machine illustration

27Check that the development unit is attached securely.

Detached

machine illustration

Attached

machine illustration

28Install the drawer stop knob, and then fasten it by turning it.

machine illustration

29Attach the cover, and then secure it with the 3 screws in order.

machine illustration

30Pull up the lever.

machine illustration

Important

  • Push up the lever as shown in the figure. An internal spring will return the lever to its original position. If the lever is held and turned, the roller may not return to the correct position, causing an error.

    machine illustration

31Engage the new charge unit with the guide rail.

machine illustration

32Push the charge unit in horizontally.

machine illustration

33Attach the cover by aligning it with the 3 catches.

machine illustration

34Secure the cover with the 3 screws.

machine illustration

35Close the front covers.

machine illustration

36Reset the counter for replaceable parts.

Do not turn the machine on until you have read how to do so.

See Resetting the Replaceable Parts Counter.