Use the “access” command to view and configure access control. You can also specify two or more access ranges.
Reference
msh> access
Configuration
msh> access range start-address end-address
represents a target number between 1 and 5. (Up to five access ranges can be registered and selected.)
Example: To specify accessible IP addresses between 192.168.0.10 and 192.168.0.20:
msh> access 1 range 192.168.0.10 192.168.0.20
The access range restricts the workstations from which printing is possible by means of an address. If you do not need to restrict printing, make the setting “0.0.0.0”.
The entry is invalid if the start address is greater than the end address.
Up to five access ranges can be specified. The entry is invalid if the target number is omitted.
Sessions other than those from a Web Image Monitor or telnet are limited by access control.
Access control initialization
msh> access flush
This restores the factory default so all access ranges become “0.0.0.0”.