Log in to Web Image Monitor in the administrator mode.
In the menu area, click [Configuration].
Under "Security", click [IEEE 802.1X].
In "User Name", enter the user name set in the RADIUS server.
Enter the domain name in "Domain Name".
Select "EAP Type". Configurations differ according to the EAP Type.
EAP-TLS
Make the following settings according to the operating system you are using:
Select [On] or [Off] in "Authenticate Server Certificate".
Select [On] or [Off] in "Trust Intermediate Certificate Authority".
Enter the host name of the RADIUS server on "Server ID".
Select [On] or [Off] in "Permit Sub-domain".
LEAP
Click [Change] in "Password", and then enter the password set in the RADIUS server.
EAP-TTLS
Click [Change] in "Password", and then enter the password set in the RADIUS server.
Click [Change] in "Phase 2 User Name", and then enter the user name set in the RADIUS server.
Select [CHAP], [MSCHAP], [MSCHAPv2], [PAP], or [MD5] in "Phase 2 Method".
Certain methods might not be available, depending on the RADIUS server you want to use.
Make the following settings according to the operating system you are using:
Select [On] or [Off] in "Authenticate Server Certificate".
Select [On] or [Off] in "Trust Intermediate Certificate Authority".
Enter the host name of the RADIUS server in "Server ID".
Select [On] or [Off] in "Permit Sub-domain".
PEAP
Click [Change] in "Password", and then enter the password set in the RADIUS server.
If [TLS] is selected for "Phase 2 Method", you do not need to specify a password.
Click [Change] on "Phase 2 User Name", and then enter the user name set in the RADIUS server.
Select [MSCHAPv2] or [TLS] in "Phase 2 Method".
When you select [TLS], you must install "IEEE 802.1X Client Certificate".
Make the following settings according to the operating system you are using:
Select [On] or [Off] in "Authenticate Server Certificate".
Select [On] or [Off] in "Trust Intermediate Certificate Authority".
Enter the host name of the RADIUS server on "Server ID".
Select [On] or [Off] in "Permit Sub-domain".
Click [OK].
“Updating...” appears. Wait for about one or two minutes, and then click [OK].
In the menu area, click [Configuration].
Under "Interface", click [Interface Settings].
Select [Active] in "Ethernet Security".
Click [OK].
“Updating...” appears. Wait for about one or two minutes, and then click [OK].
Click [Logout].
Quit the Web Image Monitor.
For details about Web Image Monitor, see Using Web Image Monitor.
If there is a problem with settings, you might not be able to communicate with the machine. To identify the problem, print the configuration page. For details about printing the configuration page, see Print List.
If you cannot identify the problem, reset the machine interface to normal, and then repeat the procedure from the beginning.