Scanning Part of an Original

This section explains how to specify a custom size for scanning part of an original.

To scan part of an original, measure Original Size (X1 and Y1), Start Position (X2 and Y2), and Scan Area (X3 and Y3) on the surface of the original, and then enter those values in the same order on the custom size setting screen.

To display the custom size setting screen, on the initial scanner screen, press [Scan Settings] > [Scan Size] > [Custom Size].

Measuring methods differ depending on the original orientation. For details about how to measure Original Size (X1 and Y1), Start Position (X2 and Y2), and Scan Area (X3 and Y3) correctly, see "How to measure sizes".

Enter the sizes while referring to "Scan settings on the custom size setting screen".

How to measure sizes

Original Orientation

Measuring method for scanning the "R" section

Original Orientation is Operation panel screen illustration or Operation panel screen illustration

Illustration of the original orientation

Original Orientation is Operation panel screen illustration or Operation panel screen illustration

Illustration of the original orientation

Scan settings on the custom size setting screen

Operation panel screen illustration numbered callout illustration

  1. Original Size (X1 and Y1)

    Specify the original's entire size.

    Enter the actual values in [X1] and [Y1] while referring to "How to measure sizes", and then press the [Sharp] key.

  2. Start Position (X2 and Y2)

    Specify the scanning start position.

    Enter the actual values in [X2] and [Y2] while referring to "How to measure sizes", and then press the [Sharp] key.

  3. Scan Area (X3 and Y3)

    Specify sizes of the area you want to scan.

    Enter the actual values in [X3] and [Y3] while referring to "How to measure sizes", and then press the [Sharp] key.

Note