Skip header
 

Checking the Earth Leakage Breaker

This section explains how to check the earth leakage breakers.

This machine and some of its options are equipped with earth leakage breakers.

For details about where they are located, see “Guide to Components”.

WARNING


  • Do not turn the earth leakage breakers from the off to the on position. Otherwise it might lead to an electric shock, or cause the circuit breakers to trip.

Once a year, check that the earth leakage breakers function properly. Normally, the breakers are in the On position.

Check all breakers in the same way.

Important

  • If the earth leakage breakers are not functioning normally, contact your sales or service representative.

1Press the operation switch to turn off the power.

2Turn off the main power.

3Using a ballpoint pen or similar pointed object, press in the earth leakage breaker's test button.

Earth leakage breaker illustration

4Check that the earth leakage breaker moves to the Off position.

Earth leakage breaker illustration

5Return the earth leakage breaker to the On position.

Earth leakage breaker illustration

6Turn on the main power.

Note

  • If the machine does not start up when you turn its main power switch back on, check whether the earth leakage breaker is in the Off position. If any breaker is in the Off position, contact your sales or service representative. Do not reset the earth leakage breaker yourself.

  • If an option does not become operational when you turn on its main power, check if any of its breakers are in the Off position. If any breaker is in the Off position, contact your sales or service representative. Do not reset the earth leakage breaker yourself.