ManualsContentsPreviousNext |
This section describes the user tools in the Timer Settings menu under System Settings.
Default settings are shown in bold type.
Auto Off Timer
After a specified period has passed, following job completion, the machine automatically turns off, in order to conserve energy. This function is called "Auto Off".
The machine status after the Auto Off operation is referred to as "Off mode", or "Sleep mode". For the Auto Off Timer, specify the time to elapse before Auto Off.
The time can be set from 1 to 240 minutes, using the number keys.
The default setting is 1 min..
Auto Off may not work when error messages appear.
The machine may not shift to "Sleep Mode" at the set time, if the main power switch has just been turned on and functions other than copier function are still in the process of starting up.
Panel Off Timer
Set the amount of time the machine waits before switching the panel off after copying has finished or the last operation is performed.
Enter a time interval between 10 seconds and 240 minutes, using the number keys.
The default setting is On, 1 minute(s).
System Auto Reset Timer
The System Reset setting automatically switches the screen to that of the function set in Function Priority when no operations are in progress, or when an interrupted job is cleared. This setting determines the system reset interval.
The time can be set from 10 to 999 seconds, using the number keys.
The default setting is On, 60 second(s).
Copier / Document Server Auto Reset Timer (copier/Document Server)
Specifies the time to elapse before copier and Document Server modes reset.
If [Off] is selected, the machine does not automatically switch to the user code entry screen.
The time can be set from 10 to 999 seconds, using the number keys.
The default setting is On, 60 second(s).
Facsimile Auto Reset Timer (facsimile)
Specifies the time to elapse before the facsimile mode resets.
The time can be set from 30 to 999 seconds, using the number keys.
The default setting is 30 second(s).
Printer Auto Reset Timer (printer)
Specifies the time to elapse before the printer function resets.
If [Off] is selected, the machine does not automatically switch to the user code entry screen.
The time can be set from 10 to 999 seconds, using the number keys.
The default setting is On, 60 second(s).
Scanner Auto Reset Timer (scanner)
Specifies the time to elapse before the scanner function resets.
If [Off] is selected, the machine will not automatically switch to the user code entry screen.
The time can be set from 10 to 999 seconds, using the number keys.
The default setting is On, 60 second(s).
Set Date
Set the date for the copier's internal clock using the number keys.
To change between year, month, and day, press [] and [].
Set Time
Set the time for the copier's internal clock using the number keys.
Enter the time using the 24-hour format (in 1 second increments).
To change between hours, minutes and seconds, press [] and [].
Auto Logout Timer
Specify whether or not to automatically log out a user when the user does not operate the machine for a specified period of time after logging in.
The time can be set from 60 to 999 seconds, in one second increments, using the number keys.
The default setting is On, 180 second(s).