Replacing the Friction Pad

Replace the friction pad when the following message appears on the control panel:

image

Important

Friction pad

detail illustration

Use the following procedure to change the friction pad:

  1. Open the ADF cover.

  2. Grasp the old friction pad firmly at both ends, and then lift it up.

    detail illustration

  3. Push down the new friction pad until it locks into place.

    detail illustration

    Make sure the friction pad shaft is correctly aligned.

    detail illustration

    Press down on the friction pad several times to make sure it is properly engaged at both ends.

  4. Close the ADF cover, pressing it down firmly until it clicks.

  5. Press the [Menu] key.

    panel keys illustration

  6. Scroll to “Maintenance” by pressing the [Up arrow key] or [Down arrow key] key, and then press the [Yes] key.

    Maintenance?       Up arrow key
     OK=Yes / or 1-9   Down arrow key
  7. Scroll to “Reset Counter” by pressing the [Up arrow key] or [Down arrow key] key, and then press the [Yes] key.

    10 Reset Counter?  Up arrow key
     OK=Yes            Down arrow key

    The following message appears:

    Reset ADF Counter? Up arrow key
     OK=Yes            Down arrow key
  8. Press the [Yes] key.

    The counter is reset and the Maintenance menu reappears.

    Press the [No] key to switch to the initial screen.