Skip to main content
Main content

Release Note


Version 1.5.6.0

1) Supported
- None
2) Fixed
- Users may be unable to log in to a Project after a Profile is synchronized to multiple devices at the same time(Serverless Edition Only).
- Scanned images are rotated if the scan settings menu is opened when the Original Orientation setting has been hidden using the AdminTool.
- Creating a subfolder on a Domain-based DFS system causes Send to Folder delivery to fail.
- GlobalScan NX fails to deliver to a Domain-based DFS destination in a network where the server acting as the Domain controller and the server controlling the DFS system are different.
- Fax delivery sometimes fails for certain device models.
3) Others
- The "Cancel" button is now grayed out when performing an update, overwrite, or leftover data installation.
- GlobalScan NX now attempts a retry when fax data reception fails.


Version 1.5.5.0a

1) Supported
- GlobalScan NX Serverless/Business Server/Business Server Lite(Available in European regions Only)/Enterprise Server Edition V1.5.5.0 now supports the following devices:
¥ Aficio MP 301SP/301SPF / Aficio MP C305SP/C305SPF
¥ MP 301SP/301SPF / MP C305SP/C305SPF
¥ DSc530SP
2) Fixed
- None
3) Others
- Modified: Operating system information


Version 1.5.5.0

1) Supported
- GlobalScan NX Serverless/Business Server/Business Server Lite(Available in European regions Only)/Enterprise Server Edition V1.5.5.0 now supports the following devices:
¥ Aficio MP 301SP/301SPF / Aficio MP C305SP/C305SPF
¥ MP 301SP/301SPF / MP C305SP/C305SPF
¥ DSc530SP
2) Fixed
- None
3) Others
- Modified: Operating system information


Version 1.5.4.2

1) Supported
- GlobalScan NX Serverless/Business Server/Business Server Lite(Available in European regions Only)/Enterprise Server Edition V1.5.4.2 now supports the following devices:
¥ Aficio MP C4502 / Aficio MP C5502 / Aficio MP C3002 / Aficio MP C3502 / Aficio MP 4002 / Aficio MP 5002
¥ MP C4502 / MP C5502 / MP C3002 / MP C3502 / MP 4002 / MP 5002
¥ DSm940 / DSm950 / DSc930 / DSc935
2) Fixed
- "Scan Size Setting" may not be applied correctly if it is configured in System > Servie/Filter Settings > Scan Settings.
- Unable to input capital and single-bytes characters as destination email address in "Send To Email" function.
- An "OutOfMemory" error or an "InsufficientMemory" error may occur when the large size document is sent via "Send To Folder" function.
- "Flow Redirector/Table Replacement" filters may cause a handling error in multi-thread, multi-job environment.
- OCR processing may result in buffer overun in memory. (GlobalScan Business Server/Business Server Lite/Enterprise Server).
3) Others
- A Windows Server 2008 R2 AD server is now supported for Active Directory Authentication. (GlobalScan NX Serverless Only).
- "Send To Email" function allows to use "Default Sender Address" as sender email address regardless of the login user's email address.
- "Send To Email" function's email address validation now can be disabled.
- The minimum supported resolution of "Image Correction Filter" is expanded to 80dpi, as inbound FAX sometimes has less than 100dpi resolution. (GlobalScan NX Business Server/Business Server Lite/Enterprise Server)
- "RICOH" logo is added to the installer and AdminTool.