05: Machine: Maintenance
0501: Execute Process Adjustment
Execute following multiple adjustments for printing at once: image density /color deviation / charge roller cleaning.
Setting Item | Remarks |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0502: Screw-on Cap to Replace
The Toner Bottle Cap closes. The Toner Bottle in use can be pulled out when the Cap is closed. Use it when you want to replace the Toner Bottle.
Setting Items | Remarks |
|---|---|
01: Black 02: Cyan 03: Magenta 04: Yellow | Press [Execute] to execute the function. |
0503: Execute Charger Unit Cleaning
It is used to clean the Charge Roller.
Setting Item | Remarks |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0506: Execute Developer Refreshing
Replace some part of developer inside the Development Unit.
Refresh the toner for print jobs if:
Background is dirty
White spots appear
Density is uneven
Black parts are faded
Setting Items | Remarks |
|---|---|
01: KCMY 02: Black 03: Special*1 | Press [Execute] to execute the function. |
*1 5th station upgrade kit is required.
0508: Manually Smooth Fusing Belt
Smooth the Fusing Belt manually.
Setting Items | Remarks |
|---|---|
01: Belt Scratches 02: Uneven Gloss (Short Time) | Press [Execute] to execute the function. |
0509: Fusing Belt Manual Smoothing Adjustment
Set the conditions for manual Fusing Belt smoothing.
Setting Items | Default Value | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|---|
01: Smoothing Time (Belt Scratches) | 120 | 60,000 | 0 | 1 | sec |
02: Smoothing Time (Uneven Gloss) | 10 |
0510: Fusing Belt Auto Smoothing Setting
Set the conditions for automatic Fusing Belt smoothing.
Setting Items | Values | Default Value |
|---|---|---|
01: Auto Execute Belt Smoothing: For Belt Scratches | Normal Frequently (Along With Density Adjustment) More Frequently Most Frequently | Normal |
02: Auto Execute Belt Smoothing: For Uneven Gloss | Off On | On |
0511: Fusing Belt Smoothing Adjustment
Set the conditions for Fusing Belt smoothing.
Setting Items | Default Value | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|---|
01: Roller Speed (Uneven Gloss) 02: Roller Speed (Belt Scratches: Short Time) 03: Roller Speed (Belt Scratches: Long Time) | 100 | 100 | 50 | 1 | % |
0512: Fuser Unit Speed Adjustment
Performs adjustment to compensate for the deviation in the rotation speed of the fusing unit. The machine adjusts the rotation speed of the fusing unit to an appropriate value.
This adjustment takes approximately three minutes. During adjustment, the machine displays a message on the control panel. Do not open the front cover of the machine while the machine is adjusting the rotation speed.
Setting Item | Remarks |
|---|---|
01: Execute | Press [Execute] to execute the function. |
Specify the nip to optimize the line speed of the fusing unit.
Setting Item | Setting Value | Default |
|---|---|---|
02: Nip Setting | Nip 1 Nip 2 Nip 3 Nip 4 | Nip 4 |
0513: Wind Fuser Cleaning Unit at Replacement
Execute this when replacing the Fuser Cleaning Unit.
Setting Item | Description |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0514: Temperature/Humidity Inside
Display temperature and humidity.
Setting Items | Remarks |
|---|---|
01: PCU Temperature 02: PCU Humidity 03: Machine Temperature 04: Temperature 05: Humidity | Displays the corresponding value. |
0515: Display System Message for When Outside Optimal Range
Specify whether to display a warning message notifying that the ambient temperature or humidity is outside the optimal range when the machine is used under an extremely hot and humid, or cold and dry environment.
Setting Item | Setting Value | Default Value |
|---|---|---|
01: High Temperature/Humidity 02: Low Temperature/Humidity | Off On | Off |
0518: Counter Setting for Operating Multiple Fuser Units
Specify the behavior of the counters on the cleaning unit and fusing belt smoothing roller when exchanging one fusing unit for another
When [Coordinate (Switch Counter Value )] is selected, the counters on the cleaning unit and fusing belt smoothing roller change after replacing the fusing unit.
When [Not Coordinate (Carry-Over Counter Value )] is selected, the counter values of the cleaning unit and fusing belt smoothing roller are carried over after replacing the fusing unit.
Setting Item | Setting Value | Default |
|---|---|---|
01: Cleaning Unit 02: Fusing Belt Smoothing Roller | Coordinate (Switch Counter Value ) Not Coordinate (Carry-Over Counter Value ) | Not Coordinate (Carry-Over Counter Value ) |
0594: ITB: Reset Belt Position at Replacement
Resets the operating conditions of the Intermediate Transfer Belt according to the belt position.
Execute this after you replace the Intermediate Transfer Belt.
Setting Item | Description |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0595: ITB: Feedback Sensor Light Intensity Adjustment
Resets the operating conditions of the Intermediate Transfer Belt according to the light intensity.
Execute this after you clean the feedback sensor or replace the Intermediate Transfer Belt.
Setting Item | Description |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0596: ITB: Feedback Sensor Initial Phase Acquisition
Resets the operating conditions of the Intermediate Transfer Belt according to the phase.
Execute this after you replace the Intermediate Transfer Belt and execute [ITB: Feedback Sensor Light Intensity Adjustment].
Setting Item | Description |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0597: ITB: Feedback Control Status
Shows the control status of the Intermediate Transfer Belt.
Check that this item displays "1" after you execute [ITB: Feedback Sensor Light Intensity Adjustment].
Setting Item | Description |
|---|---|
01: Status | Displays a value depending on the status. "1" indicates normal status, and "0" indicates abnormal status. |
0598: ITB: Speed Adjustment During Encoder Control
Resets the operating conditions of the Intermediate Transfer Belt according to its speed.
Execute this after you replace the Intermediate Transfer Belt and execute [ITB: Feedback Sensor Initial Phase Acquisition] or [ITB: Feedback Sensor Light Intensity Adjustment].
Setting Item | Description |
|---|---|
01: Execute | Press [Execute] to execute the function. |
0599: Reset Parts Counter
Resets the counter value of the replacement part.
Setting Item | Description |
|---|---|
003: Development Unit (Black): Vent Filter 004: PCU Cleaning Unit (Black) 005: PCU Cleaning Unit (Black): Cleaning Blade 007: PCU Cleaning Unit (Black): Lubrication Roller 008: PCU Cleaning Unit (Black): Lubrication Blade 009: PCU Cleaning Unit (Black): Joint 010: PCU Cleaning Unit (Black): Gears 011: PCU Cleaning Unit (Black): Cleaning Blade Side Seal 012: PCU Cleaning Unit (Black): Lubrication Blade Side Seal 013: Charger Unit (Black) | Press [Execute] to execute the function. |
014: Photoconductor Unit (Black) 017: Development Unit (Cyan): Vent Filter 018: PCU Cleaning Unit (Cyan) 019: PCU Cleaning Unit (Cyan): Cleaning Blade 021: PCU Cleaning Unit (Cyan): Lubrication Roller 022: PCU Cleaning Unit (Cyan): Lubrication Blade 023: PCU Cleaning Unit (Cyan): Joint 024: PCU Cleaning Unit (Cyan): Gears 025: PCU Cleaning Unit (Cyan): Cleaning Blade Side Seal 026: PCU Cleaning Unit (Cyan): Lubrication Blade Side Seal | Press [Execute] to execute the function. |
027: Charger Unit (Cyan) 028: Photoconductor Unit (Cyan) 031: Development Unit (Magenta): Vent Filter 032: PCU Cleaning Unit (Magenta) 033: PCU Cleaning Unit (Magenta): Cleaning Blade 035: PCU Cleaning Unit (Magenta): Lubrication Roller 036: PCU Cleaning Unit (Magenta): Lubrication Blade 037: PCU Cleaning Unit (Magenta): Joint 038: PCU Cleaning Unit (Magenta): Gears 039: PCU Cleaning Unit (Magenta): Cleaning Blade Side Seal | Press [Execute] to execute the function. |
040: PCU Cleaning Unit (Magenta): Lubrication Blade Side Seal 041: Charger Unit (Magenta) 042: Photoconductor Unit (Magenta) 045: Development Unit (Yellow): Vent Filter 046: PCU Cleaning Unit (Yellow) 047: PCU Cleaning Unit (Yellow): Cleaning Blade 049: PCU Cleaning Unit (Yellow): Lubrication Roller 050: PCU Cleaning Unit (Yellow): Lubrication Blade 051: PCU Cleaning Unit (Yellow): Joint 052: PCU Cleaning Unit (Yellow): Gears | Press [Execute] to execute the function. |
053: PCU Cleaning Unit (Yellow): Cleaning Blade Side Seal 054: PCU Cleaning Unit (Yellow): Lubrication Blade Side Seal 055: Charger Unit (Yellow) 056: Photoconductor Unit (Yellow) 059: Development Unit (Special): Vent Filter 060: PCU Cleaning Unit (Special) 061: PCU Cleaning Unit (Special): Cleaning Blade 063: PCU Cleaning Unit (Special): Lubrication Roller 064: PCU Cleaning Unit (Special): Lubrication Blade 065: PCU Cleaning Unit (Special): Joint | Press [Execute] to execute the function. |
066: PCU Cleaning Unit (Special): Gears 067: PCU Cleaning Unit (Special): Cleaning Blade Side Seal 068: PCU Cleaning Unit (Special): Lubrication Blade Side Seal 069: Charger Unit (Special) 070: Photoconductor Unit (Special) 071: Dust Shield Glass 072: Photoconductor Unit: Drum Shaft (Greasing) 073: Development Unit (Black): Case 074: Development Unit (Cyan, Magenta, Yellow): Case 075: Development Unit (Special): Case | Press [Execute] to execute the function. |
076: Development Unit (Black): Cooling Sheet 077: Development Unit (Cyan, Magenta, Yellow): Cooling Sheet 078: Development Unit (Special): Cooling Sheet 079: Around Photoconductor Drum (Black): Potential Sensor 080: Around Photoconductor Drum (C, M, Y): Potential Sensor 081: Around Photoconductor Drum (Special): Potential Sensor 082: Print Cartridge Port (Black) 083: Print Cartridge Port (Cyan, Magenta, Yellow) 084: Print Cartridge Port (Special) 085: Intermediate Transfer Belt | Press [Execute] to execute the function. |
086: Image Transfer Roller (1st Station) 087: Image Transfer Roller (2nd Station) 088: Image Transfer Roller (3rd Station) 089: Image Transfer Roller (4th Station) 090: Image Transfer Roller (5th Station) 091: Paper Transfer Bias Roller 092: ITB Lubrication Unit 093: ITB Lubrication Unit: Lubrication Roller 094: ITB Lubrication Unit: Lubricant 095: Intermediate Transfer Belt: Feedback Sensor | Press [Execute] to execute the function. |
096: Intermediate Transfer Belt: Centering Sensor 097: ITB Unit: Rollers 098: ITB Cleaning Unit 099: ITB Cleaning Unit: 1st Cleaning Roller 100: ITB Cleaning Unit: 1st Cleaning Blade 101: ITB Cleaning Unit: 1st Collection Roller 102: ITB Cleaning Unit: 1st Slider 103: ITB Cleaning Unit: 2nd Cleaning Roller 104: ITB Cleaning Unit: 2nd Cleaning Blade 105: ITB Cleaning Unit: 2nd Collection Roller | Press [Execute] to execute the function. |
106: ITB Cleaning Unit: 2nd Slider 107: ITB Cleaning Unit: 3rd Cleaning Roller 108: ITB Cleaning Unit: 3rd Cleaning Blade 109: ITB Cleaning Unit: 3rd Collection Roller 110: ITB Cleaning Unit: 3rd Slider 111: Paper Transfer Unit 112: Paper Transfer Unit: Paper Transfer Belt Unit 113: Paper Transfer Unit: Paper Transfer Belt 114: Paper Transfer Roller 115: Paper Transfer Unit: Cleaning Unit | Press [Execute] to execute the function. |
116: Paper Transfer Unit: Cleaning Blade 117: Paper Transfer Unit: Lubricant 118: Paper Transfer Unit: Lubrication Roller 119: Paper Transfer Unit: 2nd Cleaning Blade 120: Paper Transfer Unit: Paper Path 121: Paper Transfer Unit/ID Sensor 122: Transfer-Fusing Transfer: Paper Sensor 123: Fuser Unit 124: Fuser Unit: Belt 125: Fuser Unit: Fusing Roller | Press [Execute] to execute the function. |
126: Fuser Unit: Fusing Roller Bearings 127: Fuser Unit: Pressure Roller 128: Fuser Unit: Pressure Roller Bearings 129: Fuser Unit: Fusing Roller: Core Bar Temperature Sensor 130: Fuser Unit: Paper Path 133: Fusing Belt Smoothing Roller 134: Fuser Cleaning Unit 135: Fuser Cleaning Unit: Web 136: Fuser Cleaning Unit: Roller 137: Fusing Thermopile | Press [Execute] to execute the function. |
138: Waste Toner Bottle 139: Ozone Filter (Short Life) 141: Dust Filter (Short Life) 143: Tray 1 144: Tray 1: Pickup Roller 145: Tray 1: Feed Roller 146: Tray 1: Separate Roller 147: Tray 2 148: Tray 2: Pickup Roller 149: Tray 2: Feed Roller | Press [Execute] to execute the function. |
150: Tray 2: Separate Roller 151: Tray 1: Paper Path 152: Tray 2: Paper Path 153: Tray 1, 2: Paper Path 154: Tray 1, 2: Paper Feed Sensor 155: Right Drawer: Paper Path 1 156: Right Drawer: Paper Path 2 157: Right Drawer: Rotary Gate Roller (Driven) 158: Right Drawer: Paper Dust Case 159: Left Drawer: Paper Path 1 | Press [Execute] to execute the function. |
160: Right Drawer: CIS 162: Left Drawer: Cooling Belt 163: Left Drawer: Detection Unit 164: Left Drawer: Paper Path 2 167: Booklet Staple Unit: Cartridge (Front) 168: Booklet Staple Unit: Cartridge (Back) 169: Booklet Staple Unit 170: Corner Staple Unit: Cartridge 171: Corner Staple Unit 172: Punch Unit: Perforator | Press [Execute] to execute the function. |
173: Finisher: Shift Tray Paper Path 1 174: Finisher: Shift Tray Paper Path 2 175: Finisher: Staple Paper Path 1 176: Finisher: Staple Paper Path 2 177: Finisher: Signature Paper Path 1 178: Finisher: Signature Paper Path 2 179: Finisher: Punch Unit 180: Finisher: Jogger Fence 181: Finisher: Shift Tray 1: Worm Gear 182: Finisher: Shift Tray 2: Worm Gear | Press [Execute] to execute the function. |
228: Bypass Tray 229: Bypass Tray: Pickup Roller 230: Bypass Tray: Feed Roller 231: Bypass Tray: Separate Roller 232: 2-Tray LCT: Tray 3: Feed Belt 233: 2-Tray LCT: Tray 4: Feed Belt 234: 2-Tray LCT: Tray 5: Feed Belt 235: 2-Tray LCT: Tray 6: Feed Belt 236: 2-Tray LCT: Tray 7: Feed Belt 237: 2-Tray LCT: Tray 8: Feed Belt | Press [Execute] to execute the function. |
238: 2-Tray LCT: Paper Path 1 239: 2-Tray LCT: Paper Path 2 241: 2-Tray LCT: Tray 3, 4: Feed Belt 242: 2-Tray LCT: Tray 5, 6: Feed Belt 243: 2-Tray LCT: Tray 7, 8: Feed Belt 244: 2-Tray LCT: Tray 3, 4: Side Fence Sliding Shaft 245: 2-Tray LCT: Tray 5, 6: Side Fence Sliding Shaft 246: 2-Tray LCT: Tray 7, 8: Side Fence Sliding Shaft 247: 2-Tray LCT: Dust Filter 249: First Stacker: Paper Path 1 | Press [Execute] to execute the function. |
250: First Stacker: Paper Path 2 251: First Stacker: Shift Tray Drive Unit 252: Second Stacker: Paper Path 1 253: Second Stacker: Paper Path 2 254: Second Stacker: Shift Tray Drive Unit 255: Detection Exit Roller (Driven) | Press [Execute] to execute the function. |