1235: Fusing Temperature Range
BW/FC/FCS
Under conditions below, set range of fusing start temperature.
B&W/FC/FC with S
HQ is not applied in DFE
The lager value becomes, the earlier print starts. However, fusing quality may become lower.
Setting Item | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|
01: Level: BW/FC/FCS | 16 | 1 | 1 | None |
FCS
Under conditions below, set range of fusing start temperature.
FC with S
HQ is applied in DFE Setting
The lager value becomes, the earlier printing starts. However, fusing quality may become lower.
Setting Item | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|
02: Level: Clear/Special/03: Level: White/04: Level: Metallic/05: Level: Option | 16 | 1 | 1 | None |
S
Under conditions below, set range of fusing start temperature. Print using S
Only HQ is applied in DFE
The lager value becomes, the earlier print starts. However, fusing quality may become lower.
Setting Item | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|
06: Level: Clear/Special/07: Level: White/08: Level: Metallic/09: Level: Option | 16 | 1 | 1 | None |
BW/FC/FCS: Fuser Setting HQ
Under conditions below, set range of fusing start temperature.
B&W/FC/FC with S
HQ is not applied in DFE
The lager value becomes, the earlier print starts. However, fusing quality may become lower.
Setting Item | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|
10: Level: BW/FC/FCS | 16 | 1 | 1 | None |
FCS: Fuser Setting HQ
Under conditions below, set range of fusing start temperature.
FC with S HQ is applied in DFE Setting
The lager value becomes, the earlier printing starts. However, fusing quality may become lower.
Setting Item | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|
11: Level: Clear/Special/12: Level: White/13: Level: Metallic/14: Level: Option | 16 | 1 | 1 | None |
S: Fuser Setting HQ
Under conditions below, set range of fusing start temperature.
Print using S Only
HQ is applied in DFE
The lager value becomes, the earlier print starts. However, fusing quality may become lower.
Setting Item | Max. Value | Min. Value | Step | Unit |
|---|---|---|---|---|
15: Level: Clear/Special/16: Level: White/17: Level: Metallic/18: Level: Option | 16 | 1 | 1 | None |