1232: Fusing Temperature

BW/FC/FCS

Under the following conditions, adjust heat roller temperature, temperature correction, initial sheet interval.

B & W/Full Color/Full Color with Special

High Quality is not applied in DFE Setting

Setting Item

Max. Value

Min. Value

Step

Unit

01: Heat Roller Temp

200

100

1

Degree C

02: Corct Temp: Initial Feed/03: Corct Temp: Pre-Feed

30

0

04: Initial Print Interval: Low/05: Initial Print Interval

3

None

FCS

Under the following conditions, adjust heat roller temperature, temperature correction, and initial sheet interval.

Full Color Printing including Special

High Quality is applied in DFE Setting

Setting Item

Max. Value

Min. Value

Step

Unit

06: Heat Roller Temp: Clear/Special/07: Heat Roller Temp: White/08: Heat Roller Temp: Metallic/09: Heat Roller Temp: Option

200

100

1

Degree C

10: Correct Temp: Initial Feed: Clear/Special/11: Corct Temp: Init Fd: White/12: Correct Temp: Initial Feed: Option/13: Correct Temp: Initial Feed: Option/14: Correct Temp: Pre-Feed: Clear/Special/15: Corct Temp: Pre-Fd: White/16: Correct Temp: Pre-Feed: Metallic/17: Correct Temp: Pre-Feed: Option

30

0

18: Initial Sheet Interval: Low: Clear/Special/19: Init Sht Intvl: Low: White/20: Initial Sheet Interval: Low: Metallic/21: Initial Sheet Interval: Low: Option/22: Initial Sheet Interval: Clear/Special/23: Init Sht Intvl: White/24: Initial Sheet Interval: Metallic/25: Initial Sheet Interval: Option

3

None

S

Under the following conditions, adjust heat roller temperature, temperature correction, and initial sheet interval.

Printing using Special Color Only

High Quality is applied in DFE Setting

Setting Item

Max. Value

Min. Value

Step

Unit

26: Heat Roller Temp: Clear/Special/27: Heat Roller Temp: White/28: Heat Roller Temp: Metallic/29: Heat Roller Temp: Option

200

100

1

Degree C

30: Correct Temp: Initial Feed: Clear/Special/31: Corct Temp: Init Fd: White/32: Correct Temp: Initial Feed: Metallic/33: Correct Temp: Initial Feed: Option/34: Correct Temp: Pre-Feed: Clear/Special/35: Corct Temp: Pre-Fd: White/36: Correct Temp: Pre-Feed: Metallic/37: Correct Temp: Pre-Feed: Option

30

0

38: Initial Sheet Interval: Low: Clear/Special/39: Init Sht Intvl: Low: White/40: Initial Sheet Interval: Low: Metallic/41: Initial Sheet Interval: Low: Option/42: Initial Sheet Interval: Clear/Special/43: Init Sht Intvl: White/44: Initial Sheet Interval: Metallic/45: Initial Sheet Interval: Option

3

None

BW/FC/FCS: Fuser Setting HQ

Under the following conditions, adjust heat roller temperature, temperature correction, initial sheet interval.

B & W/Full Color/Full Color including Special

High Quality is not applied in DFE Setting

Setting Item

Max. Value

Min. Value

Step

Unit

46: Heat Roller Temp

200

100

1

Degree C

47: Corct Temp: Initial Feed/48: Corct Temp: Pre-Feed

30

0

49: Initial Sheet Interval: Low/50: Initial Sheet Interval

3

None

FCS: Fuser Setting HQ

Under the following conditions, adjust heat roller temperature, temperature correction, and initial sheet interval.

Full Color Printing including Special

High Quality is applied in DFE Setting

Setting Item

Max. Value

Min. Value

Step

Unit

51: Heat Roller Temp: Clear/Special/52: Heat Roller Temp: White/53: Heat Roller Temp: Metallic/54: Heat Roller Temp: Option

200

100

1

Degree C

55: Correct Temp: Initial Feed: Clear/Special/56: Corct Temp: Init Fd: White/57: Correct Temp: Initial Feed: Metallic/58: Correct Temp: Initial Feed: Option/59: Correct Temp: Pre-Feed: Clear/Special/60: Corct Temp: Pre-Fd: White/65: Initial Sheet Interval: Low: Metallic/66: Initial Sheet Interval: Low: Option

30

0

61: Correct Temp: Pre-Feed: Metallic/62: Correct Temp: Pre-Feed: Option/63: Initial Sheet Interval: Low: Clear/Special/64: Init Sht Intvl: Low: White/67: Initial Sheet Interval: Clear/Special/68: Init Sht Intvl: White/69: Initial Sheet Interval: Metallic/70: Initial Sheet Interval: Option

3

None

S: Fuser Setting HQ

Under the following conditions, adjust heat roller temperature, temperature correction, and initial sheet interval.

Printing using Special Color Only

High Quality is applied in DFE Setting

Setting Item

Max. Value

Min. Value

Step

Unit

71: Heat Roller Temp: Clear/Special/72: Heat Roller Temp: White/73: Heat Roller Temp: Metallic/74: Heat Roller Temp: Option

200

100

1

Degree C

75: Correct Temp: Initial Feed: Clear/Special/76: Corct Temp: Init Fd: White/77: Correct Temp: Initial Feed: Metallic/78: Correct Temp: Initial Feed: Option/79: Correct Temp: Pre-Feed: Clear/Special/80: Corct Temp: Pre-Fd: White/81: Correct Temp: Pre-Feed: Metallic/82: Correct Temp: Pre-Feed: Option

30

0

83: Initial Sheet Interval: Low: Clear/Special/84: Init Sht Intvl: Low: White/85: Initial Sheet Interval: Low: Metallic/86: Initial Sheet Interval: Low: Option/87: Initial Sheet Interval: Clear/Special/88: Init Sht Intvl: White/89: Initial Sheet Interval: Metallic/90: Initial Sheet Interval: Option

3

None