Skip header
 

0507 [Developer Exhaust: Result]

Display the result of the developer exhaust.

If the developer discharge fails, check the displayed code and troubleshoot the problem accordingly. If countermeasures do not work or a code that is not on the list is displayed, contact your service representative.

For details about filling/discharging developer, see the Replacement Guide.

Code

Status

Causes

Solutions

1

Succeeded (developer discharged)

-

-

2

Developer not discharged

  • The developer bottle is not attached to the outlet.

  • The developer bottle is attached to the outlet, but the outlet shutter is not open.

Detach the developer bottle, attach it to the outlet, and then try the operation again.

9

Replenishment quit forcefully

  • The front covers have been closed.

  • The power was turned off during the operation.

Open the front covers, turn on the main power, and then try the operation again.