Skip header
 

0213 [Continuous Slip Sheet Feed Mode]

Set the stop of imaging unit with continuous slip sheet feed mode.

Continuous slip sheet feeding causes the imaging unit to run idle, causing image problems including tonner dispersion, scumming, streaks, uneven gloss, and gloss streaks. You can avoid such problems by stopping the imaging unit while the inserter is running.

Setting [Stop Imaging Unit] to [On] will cause a delay because the imaging unit is stopped after it is started.

Use this option if you want to avoid the above-described image problems when continuously feeding slip sheets.

Setting Items

Values

Default Value

[Stop Imaging Unit]

[Off]

[On]

[Off]

When this is set to [On], specify the number of slip sheets to be continuously fed before the imaging unit is stopped.

Setting Items

Default Value

Max. Value

Min. Value

Step

Unit

[No. of Sheets to Stop Imaging Unit]

10

99

1

1

Sheet(s)