Skip header
 

Paper Separation

Paper is applied with charge when it passes through the PTR.

To discharge this charge, AC bias is applied to the discharge brush [10].

Feeding black or metallic media without selecting the correct media from the library will stop the machine.

This is because the constant voltage control used for separating the media from the ITB causes a ground fault due to the conductive carbon substance contained in the media.

If "Black" or "Metallic/Pearl" is selected as the paper type in [Advanced Settings] for the custom paper, the paper transfer separation voltage is automatically to set to zero. Accordingly, this setting does not need to be adjusted if the paper type setting is specified properly.