Under the following conditions, adjust heat roller temperature, temperature correction, initial sheet interval.
B & W/Full Color/Full Color with Special
High Quality is not applied in DFE Setting
Setting Item |
Max. Value |
Min. Value |
Step |
Unit |
---|---|---|---|---|
01: Heat Roller Temp |
200 |
100 |
1 |
deg |
02: Corct Temp: Initial Feed/03: Corct Temp: Pre-Feed |
30 |
0 |
1 |
deg |
04: Initial Print Interval: Low/05: Initial Print Interval |
3 |
0 |
1 |
None |