0311 Buffer Pass Unit Fan Activation Setting

Select the condition for activating the fan in the Cool Feeding Unit. When the fan stops, the mechanical noise is lower.

Setting Items

Values

Default Value

Setting

All Paper Weights

Weight 3 or Heavier

Weight 4 or Heavier

Weight 5 or Heavier

Weight 6 or Heavier

Off

Weight 3 or Heavier

Note

  • Stopping the fan deteriorates the cooling capacity and may cause blocking to occur.