Skip header
 

Use the "ipp" command to view and configure the IPP settings.

View settings

The following command displays the current IPP settings:

msh> ipp

IPP timeout configuration

Specify how many seconds the computer waits before canceling an interrupted print job. The time can be entered between 30 and 65535 seconds.

msh> ipp timeout [30–65535]

IPP user authentication configuration

Use IPP user authentication to restrict users to print with IPP. The default is "off".

msh> ipp auth {off|digest|basic}

  • User authentication settings are "basic" and "digest".

  • If user authentication is specified, register a user name. You can register up to 10 users.

IPP Keep-Alive timeout configuration

msh> ipp keepalive_timeout [1 -255]

The following message appears:

Input user number (1 to 10):

Enter the number, user name, and password.

IPP user name:user1

IPP password:*******

After configuring the settings, the following message appears:

IPP configuration changed.

IPP user name configuration

Configure IPP users according to the following messages:

msh> ipp user

The following message appears:

Input user number (1 to 10):

Enter the number, user name, and password.

IPP user name:user1

IPP password :*******

After configuring the settings, the following message appears:

IPP configuration changed.