Skip header
 

"authfree" Command

If [Simple (Limitation)] is selected under printer job authentication, the telnet authfree command can be used to specify exceptions to the printer job authentication.

For information about the login user name and password for logging into telnet, ask the administrator. For details about logging into and using telnet, see "Remote Maintenance Using telnet", Connecting the Machine/ System Settings.

View settings

msh> authfree

If print job authentication exclusion is not specified, authentication exclusion control is not displayed.

IPv4 address settings

msh> authfree "ID" range "start-address" "end-address"

IPv6 address settings

msh> authfree "ID" range6 "start-address" "end-address"

IPv6 address mask settings

msh> authfree "ID" mask6 "base-address" "masklen"

Parallel/USB settings

msh> authfree [parallel|usb] [on|off]

  • To exclude parallel and USB connections from printer job authentication, set this to "on". The default setting is "off".

  • Always specify either "parallel" or "USB".

    "parallel" can be specified when an optional IEEE 1284 interface board is installed.

Authentication exclusion control initialization

msh> authfree flush

Note

  • In both IPv4 and IPv6 environments, up to 5 access ranges can be registered and selected.