Skip header
 

Quality Maintenance

The table below shows the list of setting items. For details about their functions, see Quality Maintenance.

Image Density Adjustment

-2 to 2

Default: 0

Registration

Print Test Sheet

Tray 1, Tray 2, Tray 3, Tray 4, Tray 5, Bypass Tray, Duplex Unit

Registration

Adjustment

Horizontal: Tray 1, Horizontal: Tray 2, Horizontal: Tray 3, Horizontal: Tray 4, Horizontal: Tray 5, Horizontal: Bypass Tray, Horizontal: Back Side, Vertical: Tray 1, Vertical: Tray 2, Vertical: Tray 3, Vertical: Tray 4, Vertical: Tray 5, Vertical: Bypass Tray, Vertical: Back Side

Drum Refresh

Auto Drum Refresh

Off (default), Short, Standard, Long

Altitude Adjustment

Standard (default), High 1, High 2

Charger Output

-50V, -25V, Standard (default), +25V, +50V

Add Extra Toner

OK, Cancel

Scattered Toner Prevention

Tray 1

On, Off (default)

Scattered Toner Prevention

Tray 2

On, Off (default)

Scattered Toner Prevention

Tray 3

On, Off (default)

Scattered Toner Prevention

Tray 4

On, Off (default)

Scattered Toner Prevention

Tray 5

On, Off (default)

Scattered Toner Prevention

Bypass Tray

On, Off (default)