Skip header
 

When Using the TWAIN Driver

This section explains the relationship between resolution and scan size when using the TWAIN driver with the machine.

To specify the scan area or resolution on the machine you are using as a network TWAIN scanner directly, see the TWAIN driver Help.

If [Binary(Text)] or [Binary(Photo)] is selected in [Col./Grad.:]

The scan size determines the maximum possible resolution.

Refer to the table below for the maximum resolution available for each scan size.

Scan size and maximum resolution

Scan size

Maximum resolution (dpi)

Maximum*, 36 × 48

600

Engineering E

635

A0 × 2, A0

652

30 × 42

720

B1 JIS

753

Architecture E

899

A1 × 2, A1

923

Engineering D

981

B2 JIS

1,065

A2, A3, A4, B3 JIS, B4 JIS, Architecture C, Engineering C, Architecture A, 11 × 17, 81/2 × 14, 81/2 × 11

1,200

* The value is valid only when the file format converter is installed. When compressing data without the file format converter, the maximum resolution is limited to 150 dpi.

If [8 Colors] or [8 Colors(Photo)] is selected in [Col./Grad.:]

The scan size determines the maximum possible resolution.

Refer to the table below for the maximum resolution available for each scan size.

Scan size and maximum resolution

Scan size

Maximum resolution (dpi)

Maximum*, 36 × 48

324

Engineering E

635

A0 × 2, A0

652

30 × 42

720

B1 JIS

753

Architecture E

899

A1 × 2, A1

923

Engineering D

981

B2 JIS

1,065

A2, A3, A4, B3 JIS, B4 JIS, Architecture C, Engineering C, Architecture A, 11 × 17, 81/2 × 14, 81/2 × 11

1,200

* The value is valid only when the file format converter is installed. When compressing data without the file format converter, the maximum resolution is limited to 150 dpi.

If [Gray Scale] or [16770K colors] is selected in [Col./Grad.:] and data is compressed

The scan size determines the maximum possible resolution.

Refer to the table below for the maximum resolution available for each scan size.

Scan size and maximum resolution

Scan size

Maximum resolution (dpi)

Maximum, 36 × 48

150

Engineering E

635

A0 × 2, A0

652

30 × 42

720

B1 JIS

753

Architecture E

899

A1 × 2, A1

923

Engineering D

981

B2 JIS

1,065

A2, A3, A4, B3 JIS, B4 JIS, Architecture C, Engineering C, Architecture A, 11 × 17, 81/2 × 14, 81/2 × 11

1,200

If [Gray Scale] is selected in [Col./Grad.:] and data is not compressed

The scan size determines the maximum possible resolution.

Refer to the table below for the maximum resolution available for each scan size.

Scan size and maximum resolution

Scan size

Maximum resolution (dpi)

Maximum

198

A0 × 2

520

36 × 48

600

Engineering E

635

A0

652

30 × 42

720

A1 × 2

736

B1 JIS

753

Architecture E

899

A1

923

Engineering D

981

B2 JIS

1,065

A2, A3, A4, B3 JIS, B4 JIS, Architecture C, Engineering C, Architecture A, 11 × 17, 81/2 × 14, 81/2 × 11

1,200

If [16770K colors] is selected in [Col./Grad.:] and data is not compressed

The scan size determines the maximum possible resolution.

Refer to the table below for the maximum resolution available for each scan size.

Scan size and maximum resolution

Scan size

Maximum resolution (dpi)

Maximum

150

A0 × 2

300

36 × 48

402

A0

424

A1 × 2

425

Engineering E

432

30 × 42

471

B1 JIS

490

Architecture E

568

A1

601

Engineering D

611

B2 JIS

693

Architecture C

804

A2

850

Engineering C

864

B3 JIS

981

A3, A4, B4 JIS, Architecture A, 11 × 17, 81/2 × 14, 81/2 × 11

1,200

Note

  • You might not be able to scan large originals if the client computer has insufficient memory, is running other applications, or if its operating system has restriction settings in place.

  • Certain original types and resolution settings can reduce scanning quality.