Scan Settings

This section describes the user tools in the [Scan Settings] tab under [Scanner Features].

Important

  • Region A icon(mainly Europe)
    For details about the optional units required for this function, see "Functions Requiring Optional Configurations", Getting Started.

A.C.S. Sensitivity Level

Sets the sensitivity level for judging color/black and white for scanning originals when [Original Type] is set to [Auto Color Select].

Default: The default setting is the middle of 5 adjustment levels.

Wait Time for Next Orig.: Exposure Glass

If you want to divide your originals and scan them separately using the exposure glass and then send them together as a single job, select [Continuous Wait], [Off], or [Set Wait Time] as the waiting status.

If you specify [Batch] for the [Original Feed Type] setting, the [Wait Time for Next Orig.: Exposure Glass] setting becomes invalid.

If [Off] is selected, the machine forwards the scan data as soon as it finishes scanning each original.

If [Set Wait Time] is selected, enter the wait time in seconds (3–999) for placing additional originals with the number keys. Scanning will start if additional originals are placed and [Start] is pressed within this time. You can end scanning and begin transmission by pressing [Sharp] within this time. Once the specified time has elapsed, transmission starts automatically.

If [Continuous Wait] is selected, the machine will wait for additional originals until [Sharp] is pressed. Scanning will start when additional originals are placed and [Start] is pressed. You can end scanning and begin sending by pressing [Sharp].

If originals are placed in the ADF, transmission will start without waiting for additional originals after all originals in the ADF have been scanned, regardless of the specified settings.

If a paper misfeed occurs or any of the following operations are performed while the machine is waiting for additional originals, the countdown stops and does not start again until [Sharp] is pressed.

  • Changing the settings such as the scan settings

  • Opening the upper cover of the ADF

Default: [Set Wait Time], 60 second(s)

Background Density of ADS (Full Color)

Characteristics due to the type of paper such as nonwhiteness like newspaper or transparent originals can be reduced by correcting the scanning density.

Default: The default setting is the middle of 5 adjustment levels.

Blank Page Detect

Use the Blank Page Detect function to prevent blank pages being scanned.

If the first page of the originals is blank, the machine beeps to warn you that you might have placed blank originals.

When the Blank Page Detect function is set to [On], the outermost 1mm of an original's edge border cannot be scanned. Blank pages of custom size originals may not be detected.

This function is available only for scanning from the ADF.

The machine cannot perform blank page detection on the second or subsequent pages of an original.

Default: [On]

Reproduction Ratio

You can change the scale factor table of "Specify Reproduction Ratio" to user specified values.

Select the pre-determined scale factors, or enter any desired values.

Program / Change / Delete Scan Size

You can register, change or delete the original scan size settings to be used in [Scan Size].

The settings configured here will be displayed in [Scan Size].

Up to 5 settings can be registered.

Note

  • For details about how to change the Scanner Features, see "Accessing User Tools", Connecting the Machine/ System Settings.