Skip header
 

135: [Rdc. Init. CPM: 2 Sd.: N/H Tmp. Envir.]

Select one of the three levels of print speed reduction at normal room temperature and above.

If the temperature of the fusing unit falls below a certain point, the machine will reduce the print speed to increase fusibility.

Note

  • The setting will take effect if the ambient temperature is higher than 17 degrees in 0510: [Temperature / Humidity outside the Machine] in [Adjustment Settings for Skilled Operators]. If the ambient temperature is 17 degrees or lower, specify 134: [Rdc. Init. CPM: 2 Sd.: Low Tmp. Envir.].

Setting Item

Values

[Reduce Initial CPM: 2 Sd.: Normal/High Temp. Envrnmt.]

[Do not Reduce]: Full Speed

[Reduce Level 1]: 80 % of full speed

[Reduce Level 2]: 65 % of full speed.

[Reduce Level 3]: 50 % of full speed