Select one of the three levels of print speed reduction at normal room temperature and above.
If the temperature of the fusing unit falls below a certain point, the machine will reduce the print speed to increase fusibility.
The setting will take effect if the ambient temperature is higher than 17 degrees in 0510: [Temperature / Humidity outside the Machine] in [Adjustment Settings for Skilled Operators]. If the ambient temperature is 17 degrees or lower, specify 132: [Rdc. Init. CPM: 1 Sd.: Low Tmp. Envir.].
Setting Item |
Values |
---|---|
[Reduce Initial CPM: 1 Sd.: Normal/High Temp. Envrnmt.] |
[Do not Reduce]: Full speed [Reduce Level 1]: 80 % of full speed [Reduce Level 2]: 65 % of full speed [Reduce Level 3]: 50 % of full speed |