128: [Adjust Paper Curl: Temp. Adjustment 1]

This setting becomes effective only if 127: [Adjust Paper Curl] is set to [On].

Adjust the temperature to minimize the temperature difference between the fusing belt and pressure roller so that the difference between the heat applied to the front and back of the paper is minimized, reducing paper curling.

If the ambient humidity is 66% to 84% in 0510: [Temperature / Humidity outside the Machine] in [Adjustment Settings for Skilled Operators], specify this setting.

If the ambient humidity is 85% or higher, adjust the temperature using 129: [Adjust Paper Curl: Temp. Adjustment 2].

If the ambient humidity is lower than 65%, it is not necessary to specify this setting.

Setting Item

Max. Value

Min. Value

Step

Unit

[Adjust Paper Curl: Temperature Adjustment 1]

60

0

1

degree(s)