Skip header
 

Replacing Other Consumables

Refer to the maintenance guide provided with the new items for the replacement.

WARNING


  • Do not use a vacuum cleaner to remove spilled toner (including used toner). Absorbed toner may cause a fire or explosion due to electrical contact flickering inside the vacuum cleaner. However, it is possible to use a vacuum cleaner that is explosion-proof and dust ignition-proof. If toner is spilled on the floor, remove the spilled toner slowly using a wet cloth, so that the toner is not scattered.

CAUTION


  • Store toner (new or used), toner containers, and components that have been in contact with toner out of reach of children.


  • If toner or used toner is inhaled, gargle with plenty of water and move into a fresh air environment. Consult a doctor if necessary.


  • If toner or used toner gets into your eyes, flush immediately with large amounts of water. Consult a doctor if necessary.


  • If toner or used toner is swallowed, dilute by drinking a large amount of water. Consult a doctor if necessary.


  • When removing jammed paper or replacing toner, avoid getting toner (new or used) on your clothing. If toner comes into contact with your clothing, wash the stained area with cold water. Hot water will set the toner into the fabric and make removing the stain impossible.


  • When removing jammed paper or replacing toner, avoid getting toner (new or used) on your skin. If toner comes into contact with your skin, wash the affected area thoroughly with soap and water.


  • The inside of the machine could be very hot. Do not touch the parts with a label indicating the “hot surface”. Otherwise, an injury might occur.

  • The fusing unit becomes very hot. When installing a new fusing unit, turn off the printer and wait at least an hour after power off before replacing parts. Not allowing the printer to cool may result in burns.

Drum Unit

Important

  • Exposure to light may result in the lower performance of the drum unit. Replace the unit as quickly as possible.

  • Do not pull out the drum unit quickly or with force as it may fall.

  • Take care that nothing comes into contact with the top surface of the drum unit.

  • When holding the drum unit, grab the green grip on the left and the handle on the front together. Do not move the drum unit by only grabbing the grip. Doing so may damage the grip.

  • The color drum units (yellow, magenta, and cyan) are supplied as a single item.

When the following messages appear on the display, the black drum unit/color drum units should be replaced soon. Prepare a new Black Drum Unit/Color Drum Unit.

“Repl Rqrd Soon:PCU:Black”

“Repl Rqrd Soon:PCU:Color”

Replace the black drum unit/color drum units if any of the following messages appear on the display:

“Rplcmnt Requird:PCU:Black”

“Rplcmnt Requird:PCU:Color”

Transfer Unit

Important

  • Replace the transfer unit and transfer roller together.

When the following message appears on the display, the transfer unit and transfer roller should be replaced soon. Prepare a new Transfer Unit and Transfer Roller.

“Repl Rqrd Soon:IntTrans”

Replace the transfer unit and transfer roller if the following message appears on the display:

“Replacmnt Requrd:IntTrans”

Waste Toner Bottle

Important

  • Waste toner bottles cannot be reused.

  • Purchasing and storing extra waste toner bottles is recommended.

  • Before removing the waste toner bottle from the printer, spread paper or some other material around the area to keep toner from dirtying your workspace.

When the following message appears on the display, the waste toner bottle should be replaced soon. Prepare a new Waste Toner Bottle.

Waste Toner almost full”

Replace the waste toner bottle if the following message appears on the display:

“Waste Toner Bottle full”

Fusing Unit

Important

  • Replace the fusing unit and dustproof filters together.

When the following message appears on the display, the fusing unit and dustproof filters should be replaced soon. Prepare a new Fusing Unit and Dustproof Filters.

“Repl Rqrd Soon:FusingUnit”

Replace the fusing unit and dustproof filters if the following message appears on the display:

“Replcmnt Rqrd:Fusing Unit”