Skip header
 

When the master is wrapped around the drum

1Unlock the lever, and then pull out the drum unit.

Drum unit illustration

2Unlock the lever to open the clamp of drum unit.

Drum unit illustration

3Remove the misfed master.

Drum unit illustration

When the lever is released, the clamp will be set back. Make sure that the clamp is set correctly as shown.

Drum unit illustration

4Push the drum until it can go no further and locks into place, and then lower the lock lever.

Drum unit illustration

5Close the front cover.

Front cover illustration

Note

Preventing paper misfeeds

If paper is curled or the margin on the leading edge of the original is too narrow, perform the following:

  • Before loading paper, flatten curled paper as shown below.

    Illustration of correcting the paper curl

  • If the leading edge margin of the original is less than 5 mm (0.2 inches) or there is a solid image on the leading edge, make sure that the edge with the wider margin goes in first. Alternately, create a leading edge margin on a duplicate of the original, and then print the duplicate.

    Illustration of feeding the original from the edge with the widest margin