Skip header
 

Resetting the Replaceable Parts Counter

1Open the front covers.

Machine body illustration

2Turn the machine on.

See Turning Off/On the Power.

3Access the Adjustment Settings for Skilled Operators menu.

See "Adjustment Settings for Skilled Operators", Adjustment Item Menu Guide: TCRU/ORU.

4Press [Machine:Maintenance].

Operation panel screen illustration

5Press [Reset Replaceable Parts Counter].

Operation panel screen illustration

6Press the button of the part that has been replaced.

Operation panel screen illustration

7Press [OK], and then close the front covers.

Machine body illustration

The counter for the replaced component is reset. The setting for adjusting the machine for the replaced component is executed automatically.

8Access the Adjustment Settings for Skilled Operators menu.

See "Adjustment Settings for Skilled Operators", Adjustment Item Menu Guide: TCRU/ORU.

9Press [Machine:Maintenance].

Operation panel screen illustration

10Press [Estimated Life Already Used].

Operation panel screen illustration

11Make sure the counter has been reset.