079: [Adj Contact Timing of Ppr Trns: Small]

Adjust the timing for the intermediate transfer belt and the paper transfer unit to come into contact when adjusting paper transfer gaps.

This is enabled only if 078: [Adjust Gap of Paper Transfer] is set to [Small Gap].

Specifying lower values makes sheets of paper come into contact at an earlier timing.

Setting Item

Max. Value

Min. Value

Step

Unit

[Adjust Contact Timing of Paper Transfer: Small Gap]

0

-30

1

msec.