073: [Ppr Trns CV Start Timing: S: Side 2]

This function is available for Pro C7100X, Pro C7110X, Pro C7100SX, and Pro C7110SX.

Adjust the timing to start constant voltage control for the bias on Side 2 during paper transfer when printing in special color.

Press [+] or [-] to adjust the start timing.

Setting Item

Max. Value

Min. Value

Step

Unit

[Ppr Trns CV Start Timing: Special: Side 2]

100

0

1

msec.