After you log in, the machine automatically logs you out if you do not use the control panel within a given time. This feature is called "Auto Logout". Specify how long the machine is to wait before performing Auto Logout.
Log in as the machine administrator from the control panel.
Press [System Settings].
Press [Timer Settings].
Press [Auto Logout Timer].
Select [On].
If you do not want to specify [Auto Logout Timer], select [Off].
Enter "10" to "999" (seconds) using the number keys, and then press [].
If you make a mistake, press [Clear].
Press [OK].
Log out.
When using the standard operation panel:
Press the [Login/Logout] key. A confirmation message appears. If you press [Yes], you will be automatically logged out.
When using the Smart Operation Panel:
Press [Logout]. A confirmation message appears. If you press [OK], you will be automatically logged out.
You can specify Auto Logout settings for Web Image Monitor in [Webpage]. For details, see the Web Image Monitor Help.