Checking the Earth Leakage Breaker

WARNING


  • When this machine's circuit breaker is set to "Off", do not switch it to "On". Doing so could result in electric shock, fire, smoke, or tripping of the room's breakers.

Important

An earth leakage breaker is installed on this machine. For details about where the breaker is located, see Guide to Components.

Once a year, check that the earth leakage breaker functions properly. Normally, the breaker is in the On position.

  1. Press the operation switch to turn off the power.

  2. Turn off the main power.

  3. Using a ballpoint pen or similar pointed object, press in the earth leakage breaker's test button.

    Earth leakage breaker illustration

  4. Check that the earth leakage breaker moves to the Off position.

    Earth leakage breaker illustration

  5. Return the earth leakage breaker to the On position.

    Earth leakage breaker illustration

  6. Turn on the main power.

Note