Skip header
 

Checking the Earth Leakage Breakers

WARNING


  • When this machine's circuit breaker is set to "Off", do not switch it to "On". Doing so could result in electric shock, fire, smoke, or tripping of the room's breakers.

Important

  • If the earth leakage breakers are not functioning normally, contact your sales or service representative.

An earth leakage breaker is installed on the back side of the trimmer unit and the ring binder.

Trimmer unit

Trimmer unit illustration numbered callout illustration

  1. Earth Leakage Breaker

Ring binder

Ring binder illustration numbered callout illustration

  1. Earth Leakage Braker

Once a year, check that the earth leakage breakers function properly. Normally, the breaker is in the On position.

The explanation uses the earth leakage breaker of the trimmer unit as an example.

Check all breakers in the same way.

1Press the operation switch to turn off the power.

2Turn off the main power.

3Using a ballpoint pen or similar pointed object, press in the earth leakage breaker's test button.

Earth leakage breaker illustration

4Check that the earth leakage breaker moves to the Off position.

Earth leakage breaker illustration

5Return the earth leakage breaker to the On position.

Earth leakage breaker illustration

6Turn on the main power.

Note

  • If the machine does not start up when you turn its main power switch back on, check whether the earth leakage breaker is in the Off position. If any breaker is in the Off position, contact your sales or service representative. Do not reset the earth leakage breaker yourself.