Cleaning the Registration Roller

The registration roller can become dirty with paper dust if you print to non-standard paper.

Clean the registration roller if white dots appear on prints.

CAUTION

  • Unplug the power cord from the wall outlet before you move the machine. While moving the machine, you should take care that the power cord will not be damaged under the machine.

  • The inside of this machine becomes very hot. Do not touch parts labelled “” (indicating a hot surface).

Important

  • Do not use chemical cleaning fluids or organic solvents such as thinner or benzine.

  • Do not touch the transcription roller (the white area in the illustration below).

    image

1Turn off the power.

2Unplug the power cord from the wall outlet. Remove all the cables from the machine.

3Pull the opening lever on the front cover, and then carefully lower the front cover.

image

Be sure to set the registration roller in the position shown by the arrow in the illustration below.

image

Clean the registration roller if prints are smeared after a paper jam is cleared.

4Clean the registration roller by applying a soft damp cloth while turning it.

5Using both hands, carefully push up the front cover until it closes.

image

6Plug in the power cord securely. Connect all the interface cables that were removed.

7Turn on the power.

Note

  • When closing the front cover, push the upper area of the cover firmly.