Skip headerimage
ManualsContentsPreviousNextHelp

Setting the Gradation Correction Value

The following procedure describes adjusting the gradation correction value.

Correct the gradation in two areas: bright areas (highlights), and medium areas (midtones). [Print Test Pattern 1] is used to set the correction value for highlights, and [Print Test Pattern 2] is used for mid tones.

  1. Press the [Menu] key.

    Control panel illustration

  2. Press the [Down arrow key] or [Up arrow key] key to select [Maintenance], and then press the [OK] key.

    Operation panel screen illustration

  3. Press the [Down arrow key] or [Up arrow key] key to select [Quality Maintenance], and then press the [OK] key.

    Operation panel screen illustration

  4. Press the [Down arrow key] or [Up arrow key] key to select [Color Calibration], and then press the [OK] key.

    Operation panel screen illustration

  5. Press the [Down arrow key] or [Up arrow key] key to select [Adjust Auto Density].

    Operation panel screen illustration

    The confirmation message appears. Press [OK] to adjust Auto Density.

    The confirmation message appears when complete. Press [Exit].

    The display returns to the Color Calibration screen.

  6. In the Color Calibration menu, press the [Down arrow key] or [Up arrow key] key to select [Print Test Pattern 1] or [Print Test Pattern 2], and then press the [OK] key.

    Operation panel screen illustration

  7. When the selected sheet is printed, the confirmation message appears. Press [Continue].

    Operation panel screen illustration

  8. Press the [Down arrow key] or [Up arrow key] key to select the color you want to adjust, and then press the [OK] key.

  9. Press the [Down arrow key] or [Up arrow key] key to adjust the correction value for the selected color, and then press the [OK] key.

    Operation panel screen illustration

  10. Press [Result] to check the result by printing the calibration sheet.

    Operation panel screen illustration

  11. After printing, press [Yes] to save the settings.

    Operation panel screen illustration

  12. After completing all settings, press the [Online] key to return to the initial screen.