ManualsContentsPreviousNext |
This can be specified using Web Image Monitor.
Open a Web browser.
Enter "http://(the machine's IP address or host name)/" in the address bar.
When entering an IPv4 address, do not begin segments with zeros. For example: If the address is "192.168.001.010", you must enter it as "192.168.1.10" to connect to the machine.
The top page of Web Image Monitor appears.
Click [Login].
The administrator can log on.
Enter the login user name and login password.
Click [Configuration], and then click [IPsec] under "Security".
The IPsec settings page appears.
Select [Active] for "Encryption Key Manual Settings".
Click [Edit] under "Encryption Key Manual Settings".
Set items for encryption key manual settings in [Settings 1].
If you want to make multiple settings, select the settings number and add settings.
Click [OK].
Select [Active] for "IPsec:" in "IPsec".
Set "Exclude HTTPS Communication" to [Active] if you do not want to use IPsec for HTTPS communication.
Click [OK].