Skip header
ManualsContentsPreviousNextHelp

Replacing the Fusing Unit

CAUTION


  • The fusing unit becomes very hot. When installing a new fusing unit, turn off the printer and wait at least an hour before replacing the old fusing unit. Not allowing the unit to cool may result in burns.

  1. Open the rear cover.

    Rear side of the printer illustration

  2. Lower the rear cover until it is horizontal, and then pull it away.

    Rear side of the printer illustration

  3. If the optional duplex unit is attached, push down the lever on the right side of the duplex unit (image), and then pull it out until it stops (image).

    Duplex unit illustration

  4. Push the under board levers (image), and then pull the duplex unit out of the printer (image).

    Duplex unit illustration

  5. Lift the lock levers of the fusing unit as shown in the illustration.

    Rear side of the printer illustration

  6. Pull the fusing unit out.

    Rear side of the printer illustration

  7. Pull out the pins on both sides of the new fusing unit.

    Fusing unit illustration

  8. Push the new fusing unit into the printer.

    Rear side of the printer illustration

  9. Push the lock levers of the fusing unit down until they click.

    Rear side of the printer illustration

  10. Position the rear cover horizontally and align it with the grooves in the printer's interior.

    Rear side of the printer illustration

  11. Close the rear cover.

    Rear side of the printer illustration

  12. When the optional duplex unit was removed, push in the duplex unit along the rails in the back of the printer.

    Duplex unit illustration

  13. Securely push the duplex unit into the printer.

    Duplex unit illustration

  14. Print a configuration page to confirm that the printer works properly.

Reference