Skip headerimage
ManualsContentsPreviousNextHelp

Setting procedure of a custom size when scanning an entire original

This section explains how to specify a custom size for scanning the entire area of an original.

To display the custom size setting screen, on the initial scanner screen, press [Scan Settings] > [Scan Size] > [Custom Size].

The following custom size original is used to explain the method for specifying the scan settings on the custom size setting screen.

Custom size original to be scanned

Illustration of custom size original

Scan settings on the custom size setting screen

Operation panel screen illustration numbered callout illustration

  1. Original Size (X1 and Y1)

    Specify the length and width of the original.

    Enter the actual width and length in [X1] and [Y1], respectively, and then press the [Sharp] key.

  2. Start Position (X2 and Y2)

    Set Start Position to 0 mm (0 inch).

    Enter "0" in both [X2] and [Y2], and then press the [Sharp] key.

  3. Scan Area (X3 and Y3)

    Specify the same values as Original Size (X1, Y1).

    Enter the same values in [X3] and [Y3] as Original Size (X1 and Y1 respectively), and then press the [Sharp] key.

Note

Reference